Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1909 1
1910 1
1911 1
1912 1
1913 1
1915 1
1917 3
1918 2
1920 1
1921 1
1922 1
1924 2
1925 4
1926 1
1927 1
1928 2
1929 4
1931 1
1933 4
1934 1
1935 1
1936 2
1937 1
1938 1
1939 1
1940 1
1942 1
1943 1
1944 3
1945 1
1946 2
1947 1
1948 1
1949 1
1950 2
1951 4
1952 3
1953 3
1954 4
1955 4
1956 3
1957 5
1958 4
1959 4
1960 1
1961 6
1962 3
1963 8
1964 9
1965 10
1966 14
1967 26
1968 67
1969 94
1970 83
1971 110
1972 98
1973 111
1974 140
1975 303
1976 252
1977 203
1978 178
1979 224
1980 225
1981 238
1982 266
1983 302
1984 342
1985 361
1986 343
1987 325
1988 320
1989 339
1990 460
1991 422
1992 415
1993 413
1994 439
1995 432
1996 433
1997 508
1998 416
1999 461
2000 468
2001 448
2002 523
2003 530
2004 606
2005 699
2006 735
2007 753
2008 771
2009 775
2010 795
2011 845
2012 867
2013 950
2014 843
2015 835
2016 813
2017 883
2018 800
2019 805
2020 851
2021 885
2022 795
2023 748
2024 306

Text availability

Article attribute

Article type

Publication date

Search Results

25,645 results

Results by year

Filters applied: . Clear all
Page 1
Influence of hemolysis on routine clinical chemistry testing.
Lippi G, Salvagno GL, Montagnana M, Brocco G, Guidi GC. Lippi G, et al. Clin Chem Lab Med. 2006;44(3):311-6. doi: 10.1515/CCLM.2006.054. Clin Chem Lab Med. 2006. PMID: 16519604
BACKGROUND: Preanalytical factors are the main source of variation in clinical chemistry testing and among the major determinants of preanalytical variability, sample hemolysis can exert a strong influence on result reliability. ...Therefore, the present investigation eval …
BACKGROUND: Preanalytical factors are the main source of variation in clinical chemistry testing and among the major determinants of …
Dilution correction for dynamically influenced urinary analyte data.
Hertel J, Rotter M, Frenzel S, Zacharias HU, Krumsiek J, Rathkolb B, Hrabe de Angelis M, Rabstein S, Pallapies D, Brüning T, Grabe HJ, Wang-Sattler R. Hertel J, et al. Anal Chim Acta. 2018 Nov 22;1032:18-31. doi: 10.1016/j.aca.2018.07.068. Epub 2018 Jul 28. Anal Chim Acta. 2018. PMID: 30143216
Urinary analyte data has to be corrected for the sample specific dilution as the dilution varies intra- and interpersonally dramatically, leading to non-comparable concentration measures. Most methods of dilution correction utilized nowadays like probabilisti …
Urinary analyte data has to be corrected for the sample specific dilution as the dilution varies intra- and interpersonally dr …
Reduction of dilution error in ELISAs using an internal standard.
Verch T, Roselle C, Shank-Retzlaff M. Verch T, et al. Bioanalysis. 2016 Jul;8(14):1451-64. doi: 10.4155/bio-2016-0053. Epub 2016 Jun 17. Bioanalysis. 2016. PMID: 27314462
METHODOLOGY: We used an internal control to measure dilution bias in an ELISA. Acridine-orange was added at the first dilution step and monitored throughout dilutions. ...Correction of assay results with the measured dilution factor improved bot …
METHODOLOGY: We used an internal control to measure dilution bias in an ELISA. Acridine-orange was added at the first dilution
Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives.
Reuter DA, Huang C, Edrich T, Shernan SK, Eltzschig HK. Reuter DA, et al. Anesth Analg. 2010 Mar 1;110(3):799-811. doi: 10.1213/ANE.0b013e3181cc885a. Anesth Analg. 2010. PMID: 20185659 Review.
In this article, we review this clinical standard, along with current alternatives also based on the indicator-dilution technique, such as the transcardiopulmonary thermodilution and lithium dilution techniques. In this review, not only the underlying …
In this article, we review this clinical standard, along with current alternatives also based on the indicator-dilution techni …
Muscle Mass Assessed by the D3-Creatine Dilution Method and Incident Self-reported Disability and Mortality in a Prospective Observational Study of Community-Dwelling Older Men.
Cawthon PM, Blackwell T, Cummings SR, Orwoll ES, Duchowny KA, Kado DM, Stone KL, Ensrud KE, Cauley JA, Evans WJ. Cawthon PM, et al. J Gerontol A Biol Sci Med Sci. 2021 Jan 1;76(1):123-130. doi: 10.1093/gerona/glaa111. J Gerontol A Biol Sci Med Sci. 2021. PMID: 32442245 Free PMC article.
Associations of D3Cr muscle mass with these outcomes were slightly attenuated after adjustment for confounding factors and the potentially mediating effects of strength and physical performance. CONCLUSIONS: Low muscle mass as measured by D3Cr dilution is a novel ri …
Associations of D3Cr muscle mass with these outcomes were slightly attenuated after adjustment for confounding factors and the potent …
Stable-isotope dilution LC-ESI-MS/MS techniques for the quantification of total homocysteine in human plasma.
Tomaiuolo M, Vecchione G, Margaglione M, Pisanelli D, Grandone E. Tomaiuolo M, et al. J Chromatogr B Analyt Technol Biomed Life Sci. 2009 Oct 15;877(28):3292-9. doi: 10.1016/j.jchromb.2009.07.024. Epub 2009 Jul 21. J Chromatogr B Analyt Technol Biomed Life Sci. 2009. PMID: 19651543 Review.
Increased plasma levels of homocysteine are an independent risk factor for atherosclerosis and cardiovascular disease. Accurate and reliable quantification of this amino acid in plasma samples is essential in clinical practice to explore the presence of a hyperhomocysteine …
Increased plasma levels of homocysteine are an independent risk factor for atherosclerosis and cardiovascular disease. Accurate and r …
Energy requirements of infants.
Butte NF. Butte NF. Public Health Nutr. 2005 Oct;8(7A):953-67. doi: 10.1079/phn2005790. Public Health Nutr. 2005. PMID: 16277814 Review.
Evaluation of the 15N-isotope dilution technique for determining the recovery of endogenous protein in ileal digestion of pigs: effect of dilution in the precursor pool for endogenous nitrogen secretion.
Lien KA, Sauer WC, Mosenthin R, Souffrant WB, Dugan ME. Lien KA, et al. J Anim Sci. 1997 Jan;75(1):148-58. doi: 10.2527/1997.751148x. J Anim Sci. 1997. PMID: 9027560
The results from this study indicate that enrichments in total N in the TCA-soluble fraction of plasma may not accurately reflect enrichments in endogenous N secreted into the intestinal lumen. This factor should be considered when using the 15N-isotope dilution tec …
The results from this study indicate that enrichments in total N in the TCA-soluble fraction of plasma may not accurately reflect enrichment …
In-column dilution: Improving volume loadability in reverse phase gradient chromatography through the use of a silica pre-column.
Miller L, Ayube SJ. Miller L, et al. J Chromatogr A. 2020 May 10;1618:460897. doi: 10.1016/j.chroma.2020.460897. Epub 2020 Jan 23. J Chromatogr A. 2020. PMID: 32007218
Volume loading for RP gradient separations was significantly increased by inserting a silica column ahead of the RP separation column. The sole purpose of this column is to dilute the plug of strong injection solvent so that the actual sample constituents are retained when …
Volume loading for RP gradient separations was significantly increased by inserting a silica column ahead of the RP separation column. The s …
Formation of Diastereomeric Dihydromenthofurolactones by Cystostereum murrayi and Aroma Dilution Analysis Based on Dynamic Headspace Extraction.
Brescia FF, Pitelas W, Yalman S, Popa F, Hausmann HG, Wende RC, Fraatz MA, Zorn H. Brescia FF, et al. J Agric Food Chem. 2021 Jun 2;69(21):5997-6004. doi: 10.1021/acs.jafc.1c01478. Epub 2021 May 19. J Agric Food Chem. 2021. PMID: 34008976
Submerged cultures of the basidiomycota Cystostereum murrayi emit an intensive coconut-like, sweetish, and buttery smell. For identification of the key aroma compounds, an aroma dilution analysis using dynamic headspace was performed by adjusting the split ratio of the GC …
Submerged cultures of the basidiomycota Cystostereum murrayi emit an intensive coconut-like, sweetish, and buttery smell. For identification …
25,645 results
You have reached the last available page of results. Please see the User Guide for more information.